Here Calyos was targeting two 350W CPUs inside a 1U server chassis. The design was optimized for 75 CFM, ensuring quiet operation.

Computing

:

Server

2x CPU

Here Calyos was targeting two 350W CPUs inside a 1U server chassis. The design was optimized for 75 CFM, ensuring quiet operation.
Servers
In collaboration with Streacom, Calyos developed a 100% passive solution to cool a CPU and GPU within this desktop form factor.

Computing

:

Streacom SG10

In collaboration with Streacom, Calyos developed a 100% passive solution to cool a CPU and GPU within this desktop form factor.
Personal Computers
Using a 280mm radiator mounted above the evaporator this solution is capable of cooling a processor dissipating 300W. This is ideal for reliability critical applications due to the inherent fit and forget nature of an LHP-EE solution.

Computing

:

Workstation

Workstation AIO

Using a 280mm radiator mounted above the evaporator this solution is capable of cooling a processor dissipating 300W. This is ideal for reliability critical applications due to the inherent fit and forget nature of an LHP-EE solution.
Personal Computers
Here a very low case temperature was targeted for a 300W FPGA in a 1U chassis by transporting the heat to an area where the air exchanger size and airflow can be maximized.

Computing

:

Server

1x FPGA

Here a very low case temperature was targeted for a 300W FPGA in a 1U chassis by transporting the heat to an area where the air exchanger size and airflow can be maximized.
Servers
Here one 600W CPU, with >150W hotspots, is inside a 2U chassis with 300CFM of airflow. Transporting the heat to the rear of the chassis enabled maximum airflow.

Computing

:

Server

1x CPU

Here one 600W CPU, with >150W hotspots, is inside a 2U chassis with 300CFM of airflow. Transporting the heat to the rear of the chassis enabled maximum airflow.